Estimate MT/day from cycle inputs, film geometry and boat-set life. Three-step method used on real Met lines.
Film geometry
Cycle inputs (per roll)
How capacity is calculated
- Cycle time = Setup + Vacuum/Heat + Run time (jumbo÷speed) + Vent + Boat overhead
- Rolls/day = (1440 − cleaning minutes) ÷ cycle time
- Roll weight from width × length × micron × density
- Capacity = Rolls/day × Roll kg ÷ 1000 → MT/day